Jack has the ability to provide competencies to select components, install, set up, test, fault find, repair and maintain refrigeration systems and equipment that apply to food storage and preservation, air conditioning and air distribution equipment in buildings and premises. It includes regulatory requirements for purchasing and handling refrigerants.

UEENEEC025B Participate in refrigeration and air conditioning work and competency development activities

Jack is capable of the application of industry/enterprise policies in actively participating in work activities and in one's own competency development. It complies with established industry/enterprise procedures regarding how work is conducted, understanding responsibilities and obligations under competency development plan, following activities for developing competency, self-monitoring competency development and meeting trainee obligations for periodic reporting of competency development activities.

UEENEEE105A Fix and secure electrotechnology equipment

Jack is capable of fixing, securing and mounting techniques as apply in the various electrotechnology work functions. It encompasses the safe use of hand and portable power tools, safe lifting techniques, safe use of ladders and elevated platforms and the selection and safe application of fixing devices and supporting accessories/equipment.

UEENEEE102A Fabricate, assemble and dismantle utilities industry components

Jack is capable of basic fitting and fabrication techniques as they apply in the various utilities industry work functions. It encompasses the safe use of hand, fixed and portable power tools; cutting, shaping joining and fixing using metallic and non-metallic materials; dismantling and assembling equipment; basic mechanical measurement and marking-out and reading drawings/diagrams.

UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace

Jack is capable of the mandatory requirements of occupational health and safety and how they apply to the various electrotechnology work functions. It encompasses responsibilities for health and safety, risk management processes at all operative levels and adherence to safety practices as part of the normal way of doing work.

UEENEEJ102A Prepare and connect refrigerant tubing and fittings

Jack is capable of the basic connection of refrigeration and air conditioning piping/tubing and fittings. It encompasses the safe use of hand, fixed and portable power tools for cutting, flaring, bending, swaging, silver brazing copper tube to copper tube, bundy tube and brass and steel fittings, measurement and reading drawings and diagrams.

UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work

Jack is capable of identifying occupational health and safety hazard and risks and documenting control measures. It encompasses identifying workplace hazards, assigning levels of risk, developing control measures to eliminate and/or mitigate risks, reviewing risk control measures and maintaining documentation of hazards, risk control measures and their application in accordance with compliance procedures.

UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply

Jack is capable of attaching flexible cords, cables and plugs to electrical equipment connected to a supply up to 1,000V a.c. or 1,500V d.c. This may be incidental to or a primary and regular function of work related to a principle function in the workplace. It encompasses working safely, identifying plug configurations, selecting and using testing and measuring devices, terminating and connecting flexible cords/plugs and conductors, safety testing and reporting.

UEENEEJ113A Commission air conditioning and refrigeration systems

Jack is capable of commissioning of refrigeration and air conditioning systems. It encompasses working safely and to standards to commission the whole system and includes pre-commissioning tests, starting up the system, optimizing the refrigerant charge, basic air and water balancing and adjustment, checking and adjusting components and controls to ensure its efficient and balanced operation, and completing commissioning documentation.

UEENEEE103A Solve problems in ELV single path circuits

Jack is capable of providing known solutions to predictable problems in single path circuits operated at extra-low voltage (ELV) as they apply to various energy sector work functions. It encompasses working safely, problem solving procedures, including the use of basic voltage, current and resistance measuring devices, providing known solutions to predictable circuit problems.

UEENEEJ194A Solve problems in low voltage refrigeration circuits

Jack is capable of determining correct operation of low voltage d.c. and a.c. circuits and providing solutions as they apply to refrigeration work functions. It encompasses working safely, problem solving procedures, including the use of voltage, current and resistance measuring devices, providing solutions derived from measurements and calculations to predictable problems in single and multiple path circuits.

UEENEEJ104A Establish the basic operating conditions of air conditioning systems

Jack is capable of the determination of basic operating conditions of air conditioning systems. It encompasses working safely, determining air temperature, air flow rates and relative humidity using measurement and basic calculation methods.

UEENEEJ103A Establish the basic operating conditions of vapour compression systems

Jack is capable of the determination of the operating conditions of vapour compression systems. It encompasses working safely, determining refrigerant pressures and temperatures and relevant air and water temperatures using measurement and basic calculation methods.

UEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipment

Jack is capable of the installation of refrigeration and air conditioning systems including unitary equipment, compressors, condensers, evaporators, liquid receivers, pipework, ventilation and air handling (excluding central plant) and associated equipment. It encompasses working safely and to installation standards to match equipment with that specified for a given specification and location, connecting pipe work and components, and complete the necessary installation documentation.

UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures

Jack is capable of locating and rectifying fault(s) in composite appliances intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting.

UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring

Jack is capable of disconnecting and reconnecting composite appliances connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work).

UEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installations

Jack is capable of testing and visual inspection for verifying that a refrigeration and air conditioning system and components are safe, comply with requirements and functions as intended. It encompasses working safely, conducting compliance tests, conducting visual inspections, identifying non-compliance defects and mandatory reporting requirements.

UEENEEJ111A Diagnose and rectify faults in air conditioning and refrigeration systems and components

Jack is capable of diagnosing, repairing faults and replacing faulty components in refrigeration and air conditioning systems, components, interconnecting circuits and equipment operating at voltages up to 1,000 V a.c. It encompasses working safely, reading electrical circuit diagrams, refrigeration, hydronic and air distribution system diagrams and manufacturers reference material, sketching diagrams from traced wiring and piping systems, applying logical fault finding procedures, conducting repairs, replacing components and completing the necessary service documentation.

UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants

Jack is capable of recovery, pressure testing, evacuating, charging and leak testing recovery of refrigerants and lubricants from refrigeration systems and air conditioning systems. It encompasses working safely and to standards, following regulations and industry practices for handling refrigerants and lubricants, and completing the necessary documentation. Note:Refrigeration systems may be those used for refrigerating or for air conditioning.

UEENEEJ153A Unknown Unit UEENEEJ153A

Jack is capable of finding and repairing faults in motors and associated controls in refrigeration and air conditioning systems. It encompasses working safely, applying knowledge of motor systems and their controls, reading circuit diagrams, sketching diagrams from traced circuits, applying logical fault finding procedures, conducting repairs and completing the necessary service documentation.

UEENEEJ106A Install refrigerant pipe work, flow controls and accessories

Jack is capable of the installation, in buildings and premises, of refrigerant piping/tubing, fittings, flow control sand accessories for refrigeration and air conditioning systems. It encompasses working safely and to installation standards, routing pipe work to specified locations, connecting components and accessories and documenting installation work.

UEENEEK142A Apply environmentally and sustainable procedures in the energy sector

This competency standard unit requires Jack to undertake methods of work practice that minimises energy and material usage and to seek energy reduction strategies in the energy sector workplace. The unit seeks to minimise negative impacts on the environment.

UEENEEJ110A Select refrigerant piping, accessories and associated controls

Jack is capable of the selection of refrigerant piping, accessories and controls for refrigeration and air conditioning installations to comply with regulations, standards and specifications. It encompasses developing refrigerant pipe work arrangements, selecting pipe work and fittings, refrigerant flow controls and accessories, and mechanical and electrical control devices based on specifications, standards and manufacturer catalogues to determine calculated and deemed to comply solutions and documenting all selection information.

UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications

Jack is capable of the use of drawings, diagrams, cable schedules, standards, codes and specifications as they apply to the various electrotechnology work functions. It encompasses the rudiments for communicating with schematic, wiring and mechanical diagrams and equipment and cable/connection schedules, manuals, site and architectural drawings and plans showing the location of services, apparatus, plant and machinery and understanding the use and format of compliance standards and job specifications.

UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply

Jack is capable of attaching flexible cords and plugs to electrical equipment for connection to supplies up to 230V a.c. This may be incidental to or a primary and regular function of work related to a principle function in the workplace. It encompasses working safely, identifying plug configurations, selecting and using testing and measuring devices, terminating and connecting cords/plugs and conductors, safety testing and reporting.